Outerib Glass Insulators Manufacturer in China
Outerib glass insulators utilize a distinct design where the protective ribs are positioned on the outer skirt of the insulator. This configuration provides an exceptionally long and protected leakage path for electrical current, making them exceptionally resistant to flashovers in areas with severe air pollution, salt spray, or high levels of conductive dust. The outer rib structure effectively shields the core puncture path from the elements and pollution, enhancing overall dielectric strength. Combined with the proven durability and easy fault-spotting nature of glass, they are a robust solution for critical, contamination-heavy applications.
Nooa Energy’s 22+ electrical Outerib Glass Insulators industry experience and technically advanced team of 25 technicians ensure precise manufacturing to the highest standards. Our vast 70,000 square meter facility enables large-scale production and bulk stocking, making us a one-stop service for EPC projects requiring dependable, certified insulators that are easy to visually inspect for damage.
| basic type | minimum mechanical failing load(kn) | nominal diameter d(mm) | nominal spacing p(mm) | nominal creepage distance (mm) | standard coupling | wet power frequency withstand voltage (kv) | dry lightning impulse withstand voltage (kv) | power frequency puncture voltage (kv) | radio interference voltage (μ v) 10kv 1mhz | corona visual test p/c kv | power frequency electric arc voltage | impulse puncture voltage (p.u) | net weight (kg) |
| u70bld | 70 | 280 | 146 | 450 | 16 | 45 | 120 | 110 | 50 | 18/22 | 0.12s/20ka | 2.8 | 5.4 |
| u70blt | 70 | 320 | 155 | 550 | 16 | 45 | 120 | 110 | 50 | 18/22 | 0.12s/20ka | 2.8 | 7.5 |
| u100bld | 100 | 280 | 146 | 450 | 16 | 45 | 120 | 110 | 50 | 18/22 | 0.12s/20ka | 2.8 | 5.4 |
| u100blt | 100 | 320 | 155 | 550 | 16 | 45 | 130 | 110 | 50 | 18/22 | 0.12s/20ka | 2.8 | 7.5 |
| u120bld | 120 | 280 | 146 | 450 | 16 | 45 | 120 | 110 | 50 | 18/22 | 0.12s/20ka | 2.8 | 5.4 |
| u120blt | 100 | 320 | 155 | 550 | 16 | 45 | 130 | 110 | 50 | 18/22 | 0.12s/20ka | 2.8 | 5.4 |
| u160bmd | 160 | 300 | 155 | 450 | 20 | 45 | 130 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 7.5 |
| u160bld | 160 | 340 | 170 | 550 | 20 | 50 | 130 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 7.5 |
| u210bd | 210 | 300 | 170 | 450 | 20 | 45 | 120 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 7.5 |
| u210bd1 | 210 | 340 | 170 | 550 | 20 | 50 | 135 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 9.5 |
| u240bd | 240 | 300 | 170 | 450 | 20/24 | 45 | 120 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 9.5 |
| u240bd1 | 240 | 340 | 170 | 550 | 20/24 | 50 | 135 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 9.5 |
| u160bmt | 160 | 320 | 155 | 550 | 20 | 45 | 120 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 9.6 |
| u160blt | 160 | 320 | 170 | 550 | 20 | 45 | 120 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 9.6 |
| u210bt | 210 | 320 | 170 | 550 | 20 | 50 | 130 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 9.2 |
| u240bt | 240 | 320 | 170 | 550 | 20 | 50 | 130 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 9.2 |
| u300bd | 300 | 320 | 195 | 480 | 24 | 45 | 130 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 11 |
| u300bt | 300 | 340 | 195 | 550 | 24 | 50 | 140 | 130 | 50 | 18/22 | 0.12s/20ka | 2.8 | 12.1 |
Outerib Glass Insulators








Outerib Glass Insulators Features
- Outerib glass insulators feature ribbed surfaces on their outer design, which significantly increase creepage distance and improve resistance against surface leakage currents caused by pollution.
- Made of toughened glass, they provide exceptional mechanical strength, electrical stability, and long service life. Their ribbed profile enhances resistance to contamination while maintaining excellent insulation even in demanding conditions. The glass body offers transparency for simple defect inspection, allowing quick identification of cracks or weaknesses.
- With their durability, resistance to corrosion and UV aging, and low maintenance requirements, outerib insulators are a reliable choice for environments where stronger insulation margins are necessary.


Outerib Glass Insulators Applications
- Outerib glass insulators are extensively used in transmission and distribution lines where higher creepage distance is essential for safe operation. They are suitable for polluted, coastal, and desert environments where contaminants can compromise insulation.
- By providing additional protection against flashover, these insulators ensure consistent performance and safe energy delivery. They are commonly adopted in high-voltage grids, substations, and industrial regions requiring robust insulation solutions.
- Power utilities prefer outerib insulators for their effectiveness in maintaining grid stability while minimizing service interruptions and reducing the long-term cost of maintenance in harsh operating conditions.
Customers & Shipment About Outerib Glass Insulators


- Outerib glass insulators are uniquely designed with prominent aerodynamic ribs located on the top, weather-exposed surface of the glass bell.
- This configuration is specifically engineered to manage water flow during heavy rain and to disrupt the formation of conductive ice bridges in freezing conditions.
- By controlling water shedding and preventing ice accretion, the design provides enhanced performance in wet and icy weather while still maintaining good self-cleaning properties.
- These specialized insulators are primarily deployed in regions that experience heavy rainfall, freezing rain, or snow.
- They are particularly effective for transmission lines in mountainous and cold climates where ice buildup is a major cause of flashovers and power outages, improving grid resilience in harsh weather.
1.Number of Protective Sheds (Umbrellas)
Double-Umbrella: Two shed layers provide extended creepage distance.
Triple-Umbrella: Three shed layers provide even longer creepage distance and more surface protection.
2.Pollution Performance
Double-Umbrella: Suitable for moderately polluted environments (industrial zones, light coastal areas).
Triple-Umbrella: Designed for heavy pollution conditions (dense industrial regions, deserts, salt spray coastal areas).
3.Creepage Distance
Double-Umbrella: Medium creepage distance, adequate for most standard transmission lines.
Triple-Umbrella: Larger creepage distance, reducing leakage current risks under severe contamination.
4.Size and Weight
Double-Umbrella: More compact and lighter, easier to handle and install.
Triple-Umbrella: Heavier and bulkier, requiring stronger hardware and more careful installation.
5.Cost and Application
Double-Umbrella: More economical, often chosen when environmental conditions are not extremely harsh.
Triple-Umbrella: Higher cost, but justified for areas with persistent fog, salt, dust, or industrial pollution where reliability is critical.
Use double-umbrella glass insulators for moderate pollution environments. Use triple-umbrella glass insulators for heavily polluted, coastal, or desert regions where maximum creepage distance and durability are needed.